Modeling and Measurement of Shielding Enclosures
The shielding effectiveness (SE) of an enclosure has been simulated with CST MICROWAVE STUDIO® (CST MWS) and compared to measurement from a known reference case equipment. For the SE measurements and simulations the source was a 28-cm diameter loop (Fig. 1) fed from a shielded ACMOS digital gate rated at 8MHz clock. An essential feature of a source is that it covers an adequate bandwidth to excite the enclosure over the frequency range of interest. Furthermore, the source must be of sufficient size to adequately excite the enclosure and to have a variable polarisation and location to excite all possible cavity modes. Figure 1 also shows the simulation setup in CST MWS.
Figure 1: Simulation of the semianechoic environment and radiating loop simulated by CST MWS.
The radiating source was placed inside a shielded enclosure used for a switching telecommunication application (see Fig. 2). The structure was simulated taking only the main walls into account. The doors of the shielded rack were simulated with a perfect metal rectangular plate. The narrow slots, which were created by introducing some sheet of paper between the horizontal door sides in order to cancel the gasket benefits, were simulated with rectangular slots of size: 2 mm x 50 cm and depth of 1.5 mm. The reflecting plane of the semi-anechoic chamber was accounted for using the condition of a metallic wall (Et=0).
Figure 2: Loop in a typical shielded enclosure used by Italtel for its switching equipment.
Figure 3 compares measured and simulated values in the case of shielded enclosure with two narrow slots. The measurements were performed at two different periods in time on different enclosures of the same type and reported different values (continuous: old measurement and spotted lines: new measurement). The difference between the two measurements is probably due to the uncertainty of the EMC measurements and some slight differences in the mechanical structure such as joints, soldering, surface and gasket pressure.
Figure 3: Simulated and mesured (in two different periods of time) electric field at 3m for the shielded enclosure under test.
Despite the fact that the shielded enclosure was simulated neglecting many details, the measured and calculated emission profiles shown in Figure 3 are in good agreement. Calculated values at some frequencies are a little higher than measured ones. The apertures were not simulated with the exact same size of a narrow slot caused by sheet of papers introduced between the horizontal gaskets of the doors. Furthermore, the simulation was done without the metallic losses which leads to a higher Q of the enclosure. Less than 4 hours were needed to simulate the shielded enclosure in the described setup on a Pentium II 233 MHz, 128 MB RAM.
CST Article "Modeling and Measurement of Shielding Enclosures"
last modified 16. Dec 2005 4:26
printed 20. Nov 2008 5:36, Article ID 239
URL:
All rights reserved.
Without prior written permission of CST, no part of this publication may be
reproduced by any method, be stored or transferred into an electronic data processing system, neither mechanical or by any other method.
Article ID: 239
Last modified: 16. Dec 2005 4:26
Other Articles
The article presents an antenna-based approach to near-field imaging and spectroscopy, which can be used for both continuous-wave and pulsed broadband electromagnetic radiation from microwave to terahertz frequencies. CST MICROWAVE STUDIO® (CST MWS) was used to perform the simulations.
Read full article..
In this article CST MICROWAVE STUDIO® (CST MWS) is applied to evaluate the radiated emissions due to a metallic enclosure when a loaded monopole antenna is located inside it. Good agreement with the measurements performed in a semi-anechoic chamber is obtained.
Read full article..
CST MICROWAVE STUDIO® and Agilent ADS have been successfully employed in this OEIC driver design - an example of a high speed analog/broadband IC application.The package model was imported from Agilent momentum and the model was simulated upto a 100 GHz in CST MWS.The resulting eye diagrams of the driver design from CST MWS are compared with those from Agilent momentum and other test cases.
Read full article..
We present the RCS and surface current simulation for an electrically large helicopter. The simulation is done using a plane wave excitation at 7GHz. The helicopter is approximately 180 wavelengths in size. The calculation is performed with the Integral Equation solver of CST MICROWAVE STUDIO® using the Multilevel Fast Multipole Method. The solver is very accurate and efficient in terms of complexity for simulating electrically large structures.
Read full article..
This article concerns the application of CST MICROWAVE STUDIO® (CST MWS) to the simulation of electrically large automotive structures. CST MWS is ideal for such applications since the geometry can be easily imported and modified using the powerful user interface, the accurate and robust PERFECT BOUNDARY APPROXIMATION (PBA)® approximation is exploited, the linear scaling of memory with increasing mesh cells and the ability to simulate broadband in one single simulation. An example of an on-glass antenna simulation is also demonstrated highlighting the versatility of the CST MWS Transient solver.
Read full article..